Skip to content

Power System Protection & Relay Coordination Training Course

Teaches engineers to design, set, coordinate, test and maintain protection relays that clear faults quickly and isolate only the faulted part of the system.

ELE · Electrical EngineeringAll Levels#2358ClassroomEnglish , Arabic
Duration
5 Days
Download BrochureView Upcoming Dates

Free substitution at any time · 30+ days' notice: full refund minus 10%. Cancellation policy

Course Overview

The Power System Protection & Relay Coordination Training Course equips electrical and protection engineers with the principles, practical methods, and tools needed to design, set, coordinate, test, and maintain protection systems that detect faults quickly, isolate only the faulted part of the system, and protect people and equipment. In oil and gas facilities, petrochemical and industrial plants, power generation, transmission, and distribution utilities, water and desalination plants, and large infrastructure, protection maloperations and poor coordination can cause equipment damage, widespread outages, safety incidents, and significant production and service losses. The course covers protection from fundamentals to field practice. Participants learn protection philosophy and requirements, zones of protection, fault types and fault calculation basics, instrument transformers, numerical relays and intelligent electronic devices, and standard protection functions and device numbers. The program then addresses protection of feeders, transformers, generators, motors, busbars, transmission and distribution lines, and capacitor banks, including overcurrent, earth fault, directional, differential, distance, and restricted earth fault protection and auto-reclosing, along with earthing systems and their effect on earth fault protection. Participants also develop relay coordination skills using standard time-current characteristics, grading margins, and coordination studies, examine arc flash reduction schemes, IEC 61850-based digital substations, relay testing and commissioning, settings management, disturbance record analysis, and troubleshooting of protection maloperations. The course is delivered through worked examples, relay setting and coordination exercises, case studies of protection maloperations, and fault record analysis. Participants leave with a protection philosophy and requirements checklist, relay setting calculation worksheets, a coordination study template, a relay testing and commissioning checklist, and a protection maloperation investigation guide.

Learning Objectives

  • Analyze protection system philosophy and requirements, including reliability, selectivity, speed, sensitivity, security, and dependability, on Day 1.
  • Apply zones of protection, fault types, and fault calculation fundamentals, including symmetrical components, to protection design.
  • Evaluate current and voltage transformers, including accuracy classes, saturation, and their effect on protection performance.
  • Explain the operation of numerical relays and intelligent electronic devices and standard protection functions and device numbers.
  • Apply overcurrent, earth fault, and directional protection to radial and interconnected feeders.
  • Apply transformer protection, including differential, restricted earth fault, overcurrent, and mechanical protection.
  • Apply generator and motor protection, including differential, loss of excitation, reverse power, negative sequence, thermal, and stall protection.
  • Apply busbar, line, and capacitor bank protection, including busbar differential, distance, line differential, pilot schemes, and auto-reclosing.
  • Evaluate earthing systems and their impact on earth fault detection and protection settings.
  • Perform relay coordination using standard time-current characteristics, grading margins, and coordination studies.
  • Apply arc flash reduction schemes and evaluate IEC 61850-based protection and digital substation concepts.
  • Plan relay testing and commissioning, manage protection settings, analyze disturbance records, and investigate protection maloperations by the end of Day 5.

Who Should Attend

This course is designed for protection engineers, electrical engineers, power system engineers, and substation engineers responsible for designing, setting, or maintaining protection systems. It is also relevant for relay testing and commissioning engineers and technicians, electrical maintenance engineers and supervisors, control and SCADA engineers working with substations, and engineers moving into protection roles. It is particularly valuable for professionals in power generation, transmission, and distribution utilities; in oil and gas, refining, petrochemical, and industrial facilities; in water and desalination plants; in engineering, procurement, and construction contractors and electrical consulting firms; and in data centers, airports, and large infrastructure projects.

Learning Outcomes

  • By the end of the course, participants will be able to:
  • Explain the principles and requirements of effective protection systems.
  • Define protection zones and understand how faults affect power systems.
  • Select and evaluate current and voltage transformers for protection.
  • Understand how numerical relays and protection functions work.
  • Set overcurrent, earth fault, and directional protection correctly.
  • Apply suitable protection schemes to transformers, generators, and motors.
  • Apply busbar, line, and capacitor protection schemes.
  • Understand how earthing arrangements affect earth fault protection.
  • Coordinate protective devices to achieve selectivity.
  • Apply schemes that reduce arc flash hazards.
  • Plan relay testing and commissioning effectively.
  • Analyze fault records and investigate protection maloperations.

Course Outline

Course Outline:

Day 1

Protection Fundamentals

  • Protection philosophy and requirements
  • Zones of protection and fault types
  • Fault calculation fundamentals and symmetrical components
  • Current and voltage transformers for protection
  • Practical application: participants define protection zones and evaluate current transformer performance for a case study system
Day 2

Relays, Feeder Protection, and Earthing

  • Numerical relays, intelligent electronic devices, and standard protection functions
  • Overcurrent and earth fault protection
  • Directional protection for interconnected systems
  • Earthing systems and earth fault protection
  • Practical application: participants calculate overcurrent and earth fault settings for feeders
Day 3

Transformer, Generator, and Motor Protection

  • Transformer differential, restricted earth fault, overcurrent, and mechanical protection
  • Generator protection functions
  • Motor protection functions
  • Setting considerations and common pitfalls
  • Practical application: participants develop protection settings for a transformer, a generator, and a large motor
Day 4

Busbar, Line Protection, and Relay Coordination

  • Busbar differential protection
  • Distance, line differential, pilot schemes, and auto-reclosing
  • Capacitor bank protection
  • Relay coordination using time-current characteristics and grading margins
  • Practical application: participants perform a relay coordination study for an industrial distribution system
Day 5

Advanced Topics, Testing, and Maloperation Analysis

  • Arc flash reduction schemes
  • IEC 61850-based protection and digital substations
  • Relay testing, commissioning, and settings management
  • Disturbance record analysis and protection maloperation investigation
  • Final workshop: participants analyze fault records from case studies, identify causes of maloperations, and recommend corrective actions

Upcoming Dates

Selected date

Paris · 16 – 20 Nov 2026 · Classroom

Need more details?Chat with us on WhatsApp

CityDatesPrice per ParticipantEarly Bird
MunichScheduled
2 – 6 Nov 2026€6,000—
MuscatScheduled
9 – 13 Nov 2026€6,300—
OnlineScheduled
15 – 19 Nov 2026€2,700—
ParisScheduled
16 – 20 Nov 2026€6,700—
RiyadhScheduled
23 – 27 Nov 2026€4,800€4,320until 2 Nov
RomeScheduled
30 Nov – 4 Dec 2026€7,000€6,300until 9 Nov
ViennaScheduled
7 – 11 Dec 2026€6,400€5,760until 16 Nov
AmmanScheduled
13 – 17 Dec 2026€4,000€3,600until 23 Nov
AmsterdamScheduled
21 – 25 Dec 2026€6,000€5,400until 30 Nov
BakuScheduled
28 Dec 2026 – 1 Jan 2027€5,300€4,770until 7 Dec
BangkokScheduled
28 Dec 2026 – 1 Jan 2027€6,700€6,030until 7 Dec
BarcelonaScheduled
4 – 8 Jan 2027€6,000€5,400until 14 Dec
BerlinScheduled
11 – 15 Jan 2027€6,300€5,670until 21 Dec
CairoScheduled
18 – 22 Jan 2027€3,800€3,420until 28 Dec
CasablancaScheduled
25 – 29 Jan 2027€4,700€4,230until 4 Jan
DammamScheduled
1 – 5 Feb 2027€4,800€4,320until 11 Jan
DohaScheduled
8 – 12 Feb 2027€4,700€4,230until 18 Jan
DubaiScheduled
14 – 18 Feb 2027€4,700€4,230until 25 Jan
FrankfurtScheduled
15 – 19 Feb 2027€6,200€5,580until 25 Jan
GenevaScheduled
22 – 26 Feb 2027€7,300€6,570until 1 Feb
IstanbulScheduled
1 – 5 Mar 2027€5,300€4,770until 8 Feb
Kuala LumpurScheduled
8 – 12 Mar 2027€4,700€4,230until 15 Feb
LisbonScheduled
15 – 19 Mar 2027€6,000€5,400until 22 Feb
LondonScheduled
22 – 26 Mar 2027€5,800€5,220until 1 Mar
MadinahScheduled
29 Mar – 2 Apr 2027€4,800€4,320until 8 Mar
MadridScheduled
5 – 9 Apr 2027€6,000€5,400until 15 Mar
MakkahScheduled
5 – 9 Apr 2027€4,800€4,320until 15 Mar
ManamaScheduled
12 – 16 Apr 2027€5,300€4,770until 22 Mar
Sharm El-SheikhScheduled
19 – 23 Apr 2027€5,300€4,770until 29 Mar
MarrakeshScheduled
19 – 23 Apr 2027€4,700€4,230until 29 Mar

Available in: Istanbul · Dubai · London · Riyadh · Doha · Amsterdam

Related Courses

Ready to Elevate Your Team's Capabilities?

Speak with our advisors about upcoming programmes or a bespoke corporate training plan.